型号
|
公称直径
mm
|
B
mm
|
C
mm
|
L
mm
|
S
mm
|
X
mm
|
排污管
mm
|
流量
T/h
|
重量
kg
|
功率
W
|
SD-32Z
|
32
|
265
|
230
|
630
|
220
|
400
|
20
|
9
|
22
|
20
|
SD-40Z
|
40
|
280
|
230
|
630
|
220
|
405
|
20
|
12
|
27
|
25
|
SD-50Z
|
50
|
280
|
250
|
700
|
255
|
415
|
25
|
19
|
34
|
30
|
SD-65Z
|
65
|
280
|
250
|
700
|
255
|
415
|
25
|
28
|
42
|
40
|
SD-80Z
|
80
|
310
|
270
|
790
|
260
|
470
|
32
|
50
|
48
|
50
|
SD-100Z
|
100
|
310
|
270
|
950
|
310
|
580
|
32
|
80
|
58
|
50
|
SD-125Z
|
125
|
335
|
280
|
1000
|
365
|
590
|
40
|
25
|
66
|
70
|
SD-150Z
|
150
|
335
|
280
|
1000
|
365
|
590
|
40
|
180
|
82
|
70
|
SD-200Z
|
200
|
360
|
290
|
1020
|
365
|
610
|
50
|
320
|
115
|
80
|
SD-250Z
|
250
|
390
|
300
|
1260
|
465
|
770
|
50
|
490
|
138
|
170
|
SD-300Z
|
300
|
410
|
310
|
1300
|
490
|
800
|
50
|
710
|
184
|
210
|
SD-350Z
|
350
|
465
|
370
|
1500
|
575
|
900
|
65
|
970
|
222
|
250
|
SD-400Z
|
400
|
515
|
370
|
100
|
575
|
985
|
65
|
1400
|
334
|
330
|
SD-450Z
|
450
|
530
|
380
|
1650
|
580
|
1080
|
65
|
1590
|
387
|
410
|
|
1、设计选用时,一般按管径匹配选用的原则。设备的处理流量应大于系统实际最大流量,并有一定的富余量。
2、当系统水质复杂、硬度高时,应先大一型号的设备,可与本公司技术部取得联系,共同研究解决。
3、SD型电子水处理仪应布置在主要保护设备前,尽量靠近被保护设备,使进入被保护设备的水全部经过水处理仪。
4、SD电子水处理仪占用空间很小,仅需在主机上方留300mm检修空间,注意防水。
5、SD电子水处理仪应尽量安装在室内,如必须安装在室外,应加盖防雨装置。
|